Add Clinical Chemistry Analyzer to My Bench28 Results
1 ReplyMindray Bs 200e Brochure
I try to connect with BS-200E via TCP/IP after I set up our LIS destinate IP/Port on the analyzer and connect successfully but I still didn't receive the result from our application (The send button is enable but I don't want to send manually) Please help me.
Mindray Ultrasound Manual
1 ReplyHello.I am working on LIS and have a problem with sending samples to analyzer. Receiving result works well, but sending samples.. well not at all. Communication seems good i received ACK^Q03 every sent sample, but they don't register in software.So I have some question:1. What about DSP - 29 filed where tests number are set. How it should look when I use 'Code on LIS' mapping? It should contains only number? Like ex. DSP|29||1^^^||| 2. Where can I find 'ItemID.ini' file which is mention in 'Host Interface Manual'? It doesn't appear in installation folder.3. Is there analyzer (BS-200) is required to register samples in software? Because manually you can, maybe there is restriction for downloading samples.4. There is any chance to use 'Code on LIS' mapping instead of numbers fixed? Ex:DSP|29||1^^^||| -> DSP|29||^AMY^^|||
![Mindray Bs 200e User Manual Pdf Mindray Bs 200e User Manual Pdf](/uploads/1/2/5/1/125150169/301687040.jpg)
I have developed an App that connects my LIS to analyzer Mindray BS-200 using hl7 protocol via TCP. Everything worked correctly, the results are received from the analyzer and the requests of test are sent successfully to analyzer. The only problem I have met is that, when i send a request of test to analyzer, the sample position is not assigned, it still be blank. Consequently, the process of analyzing can not be launched; since the position field is empty.I would appreciate any advise for solving this problem.
Mindray Bs 200e User Manual Pdf 2 10
1 Replyhow i solve this for continue
0 RepliesMy bs200 shows reaction disk temperature is 44c .but i measure it was about 32c. And software starting time also it show 44c. But room temperature about 32c. Whats problem.? When i remove the reaction disk cover and top heater and cuvets hanging disk temperature down as 37c. Pls help me to solve this.
0 RepliesMy bs200 shows reaction disk temperature is 44c .but i measure it was about 32c. And software starting time also it show 44c. But room temperature about 32c. Whats problem.? When i remove the reaction disk cover and top heater and cuvets hanging disk temperature down as 37c. Pls help me to solve this.
Mindray Bs 200e User Manual Pdf 2 8
1 ReplyOur equipment is no longer reading the sample bar code. Unbelievably the problem began after the technician visit for periodic maintenance. Any idea how to solve the problem? The responsible company here in Brazil is not being able to solve. Thank you!
2 RepliesHi all,I try to connect with BS-200E via TCP/IP LAN cable after I set up our LIS destinate (IP/Port) on the analyzer and start Connect successfully but I still cannot transfer the result from our application (The Send button is enabled but we don't receive any HL7 message)Please help me.
1 ReplyMindray Bs 200e Manual
When i like configure the LIS in the software the system showme the error exist conflict with LIS. Any suggestion?I don't disable LIS, change IP o any other change
1 ReplyWhen my LIS receive message with type ORU^R01 (contains the Sample result OBX,OBR) it respond s with ACK^R01 this cause the mindray bs-200 software to shutdown!!! I couldn't explain that since I followed the instructions in the manual, any help will be nice , thank you in advance